Welcome to Guangzhou Elephant Digital Technology Co., Ltd.

Sitemap | China

Keywords:

Korea heat transfer vinyl| Cutting plotter| EPSON printhead
86-20-85643576
86-20-89015371

E-mail:dbxsublimation@transferchina.cn
Address:ROOM508-509 Fortune Center, No. 317 Dongxing Road, Dalong Street, Panyu District, Guangzhou City

Position: Home > News Center >

Routine maintenance of the machineCategory

Time:2017-09-22 09:44Source:Guangzhou Elephant Digital Technology Co., Ltd.Read:

 Routine maintenance of the machine 
1.
Grating need to cleaned with alcohol, beacuse it will have the ink stains and dust when you use for a long time
2.
Limit, when  cleaning   the nozzle, cleaning fluid and water do not add too full, otherwise easy to splash limit, so that the limit is not easy to use
3.
The ink station cap need to keep cleaning because  the ink station cap is driectly  attached to the nozzle
4.
Keep the wiper clean at all times, as the wiper is directly attached to the nozzle
5.
The black insurance at the bottom, both two  sides of the print head is kept clean, especially inside and outside the spray room, because there is a fluffy cloth
6.
Ground wrie  must be connected, requiring steel grounding 1.5 meters, and add a bag of saline water into the room, to maintain a certain humidity, the machine should often use cloth to wipe, otherwise there will be static electricity, will cause flying ink
7.
Voltage regulator, each machine should be equipped with voltage regulator, otherwise, once the voltage instability or sudden power failure, will cause a burning nozzle or motherboard, trolley board, voltage regulator minimum 3000W
8.
Press the wheel when the machine does not work
9.
 frequent move of the slide need to use the grease , but must not butter
10.
 If the nozzle is broken, the number of needles is less, it will not affect the quality of painting, cleaning or filling can be, if there are many broken needles, please timely bubble nozzle
11.
The machine is used for a long time should check whether there is loose
12.
 After starting the first cleaning, playing test whether there is broken needle, if there is broken needle cleaning or filling, before the shutdown also need to wash, hit the test
13.
Empty the ink pail in time
14.
Platform suction port will be blocked for a long time to use it , you need to cleaning it use toothpicks
15.
Computer system or reinstall software, do not have anti-virus software